<LOGO>
FM Transmitter Measurement Report
Created: 2025-12-16 15-26-58
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 4/5, 39 dBuV SANDELS
Pilot RDS Phase Difference
5.9 kHz 5.0 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
19 kHz 24 kHz 3864 0,0000
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
3,1 dBr 4,59 dBr 6,2 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
92.0, 94.7, 106.4, 107.5 MHz -
FM Scope Max at: 24 kHz MIN: 19 kHz % above 76 kHz: 0,0000 Acquired: 2025/12/16 15.25.53 Total samples: 3864 Equivalent time: 0:03:13 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 50 100 150 200
FM Scope MAX: 6,2 dBr MIN: 3,1 dBr AVE: 4,59 dBr % above 12,2 dBr: 0,0 Last value: 4,2 dBr (2025/12/16 15.25.53) 15.12 15.14 15.16 15.18 15.20 15.22 15.24 0 2 4 6 Pm [dBr]